8550 Hansen Road Houston, Texas 77075 (Ph) 713.943.0688 (Fx) 713.944.9445 www.wattsacv.com
01/05
R
Classic Series
TWO-WAY FLOW ALTITUDE VALVE
F127-2 (Globe)
F1127-2 (Angle)
Operation
The Watts ACV Two Way Flow Altitude Valve is designed to open, allowing flow into a reservoir or elevated
storage tank (tank fill), and close drip tight when high water level is achieved. The valve also opens, allowing
return flow (tank discharge), when upstream pressure falls below reservoir head pressure. The Altitude Pilot
remotely senses static tank head pressure (water level) through a field installed sensing line, and directs
pressure into and out of the cover chamber of the 3-way Accelerator Pilot. When the cover of the Accelerator
Pilot is pressurized, the main valve cover chamber is vented downstream (dry drain) or to atmosphere (wet
drain), causing the valve to open fully. When the cover of the Accelerator Pilot is de-pressurized, the main
valve cover chamber is connected to upstream pressure, causing the valve to close drip tight.
As water level decreases, static tank head pressure falls below the adjustable setpoint of the Altitude Pilot,
causing it to pressurize the cover of the Accelerator Pilot, opening the valve. As water level increases, static
tank head exceeds the adjustable setpoint of the Altitude Pilot, causing it to depressurize the cover of the
Accelerator Pilot, closing the valve drip tight. Valve opening and closing speeds are separately adjustable.
The Position Indicator with Air Bleed Petcock allow for visual indication of valve position and easy venting of
air entrapped in the main valve cover chamber.
When upstream pressure falls below reservoir head pressure, a Check Valve installed in the pilot control
system “Return Flow Line” opens, connecting the main valve cover chamber to the upstream pressure
zone, causing the valve to open allowing reservoir pressure to return into the upstream pressure zone (Tank
Discharge).
Specify Tank height PRIOR to ordering.
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - Classic Series

8550 Hansen Road • Houston, Texas 77075 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.wattsacv.com01/05RClassic SeriesTWO-WAY FLOW ALT

Strona 2

8550 Hansen Road • Houston, Texas 77075 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.wattsacv.com01/05RClassic SeriesTWO-WAY FLOW ALT

Powiązane modele: F127-2

Komentarze do niniejszej Instrukcji

Brak uwag